Sets how many void labels the printer will produce before stopping when an RFID tag fails to encode. Void labels are printed with "VOID" across them.

When to use

Production lines — controls how many failed tags are tolerated before the printer pauses for operator attention.

Syntax

^RNn

Parameters

ParameterDescription
nNumber of retries/void labels before error (0 = no limit)

Example

^XA
^RN3
^XZ

Allow 3 RFID encoding failures before stopping